Ceiling cassette air conditioning unit recessed into a suspended ceiling

Air conditioning for
schools and nurseries

A class of thirty children gives off about as much heat as a two kilowatt heater left on all day, and most London schools were built to keep the cold out. The hot weeks now fall in term time, in the summer term and in exams.

  • Free survey and heat load calculation on jobs over 5,000 pounds
  • Quote split into plant, install, electrics and out-of-hours
  • Out of hours fitting where the business cannot close

Accredited, and fitting the brands you know

NICEIC approved contractorGas Safe RegisterMCS certifiedRECC, Renewable Energy Consumer CodeTrustMark, Government Endorsed QualityVaillantClivetSamsungDaikinMitsubishi ElectricBosch

Air conditioning we have fitted

Our own jobs, photographed on site. Real rooms, real outdoor positions, nothing from a catalogue.

All our installations

A classroom is sized from its occupancy first: allow roughly 70W of heat per child and 100W per adult, then add the screens and the sun. A standard classroom of about 55 square metres with thirty pupils usually needs 4 to 6kW of cooling, split across two indoor units so the room has no warm corner.

There is no legal maximum temperature for a classroom. The Department for Education's design guidance on thermal comfort, BB101, sets out what a comfortable classroom should achieve, and it is the document a governing body or trust will usually point to.

Read the full guide: 6 sections, about 3 minutes

Where the heat in a classroom comes from

Schools and nurseries: what drives the load
SourceWhat it contributesWhy it matters
PupilsRoughly 70W each, so about 2kW for a class of thirtyThe biggest load, and it arrives all at once at 9am
StaffRoughly 100W eachSmall in a classroom, significant in a nursery room with high ratios
Screens and ITAn interactive board and a PC, and thirty more in an IT suiteAn IT suite is sized as an IT suite, not as a classroom
Sun through large windowsLarge on south and west elevations, and schools have a lot of glassBlinds and solar film are cheaper than plant, and worth doing first
Halls and kitchensCooking, and two hundred people in a hall at lunchtimeSized separately, and a hall often needs ventilation more than cooling

Fitted in the holidays, not in term

Most school work is done over the summer holiday, at Easter or at half term, when the building is empty and the noisy part of the job, drilling through walls and running pipework, disturbs nobody.

That makes the timing simple to plan backwards: survey and design in the spring term, equipment ordered before the holiday, installation in the first weeks of it, and commissioning before the site team goes on leave.

Where something has to happen in term time, it is planned with the site manager around the timetable and done under the school's own signing-in and safeguarding procedure.

Nurseries and baby rooms: quiet, gentle and out of reach

A sleep room needs an indoor unit that is quiet at its lowest fan speed and positioned so the air never blows straight onto a cot. Most modern wall units can be set to a gentle low-speed mode that is quieter than the room itself.

Controls go out of reach of children, the indoor unit goes high on the wall, and the temperature range can be limited so nobody sets a baby room to 17 degrees on a hot afternoon.

Many London nurseries are in converted houses, which makes the installation closer to a domestic multi-split than to a school system, and usually quicker and cheaper.

Ventilation is a separate question

A split air conditioning system cools and dries the air that is already in the room. It does not bring fresh air in, and it does nothing about the carbon dioxide that builds up in a full classroom.

We will not sell a cooling unit as a ventilation fix. Where a room is stuffy rather than hot, the answer is ventilation, and we will say so at the survey rather than fit the wrong thing.

What it costs

Schools are quoted from a heat load calculation and a drawing, and the quote separates plant, installation, electrical work and any builders work. The figures below are indicative and built from the same model as the rest of the site.

Schools and nurseries: indicative installed prices
ScopeUsual systemIndicative price
One classroom1 to 2 ceiling cassettes or wall units£2,900 to £7,600
Nursery room or baby room1 wall unit, quiet at low speed£2,400 to £3,500
Server or comms cupboardDedicated unit, runs all year£2,400 to £3,500
Several classrooms or a whole blockMulti-split or VRFFrom heat load and drawing
Maintenance, per unitOne visit a year, in a holidayFrom £95 plus VAT

Every figure on this site is an estimate built from the quotations we issued in 2026 and our own installation experience. It is not a quotation. The price you are given after the free survey is the price you pay.

Other commercial work

A ceiling cassette air conditioning unit fitted in a commercial space

Your estimate

£2,400to£3,200

Supplied, fitted, commissioned and certificated. Includes VAT.

Price it for schools and nurseries

Commercial work is priced on the number of indoor units and what kind they are, the same as anywhere else. The heat load calculation at the survey is what turns this into one number.

How many indoor units?
Which indoor unit?

Last step: where do we send your written price?

Every figure on this site is an estimate built from the quotations we issued in 2026 and our own installation experience. It is not a quotation. The price you are given after the free survey is the price you pay.

Schools and nurseries: common questions

Is there a maximum temperature for a classroom?

No. There is no legal maximum temperature for classrooms or for workplaces in the UK. Employers have a duty to keep the temperature reasonable for staff, and the Department for Education's guidance, BB101, sets out the thermal comfort a classroom should achieve.

In practice the question a school asks is simpler: which rooms are unusable in June, and what would it take to fix those first.

Can you install during the school holidays?

Yes, and that is how most school work is done. The survey and the design happen in term, the installation in the holiday.

The summer holiday books up first, so a survey in the spring term is the way to be sure of the dates.

Will it be noisy in a classroom or a sleep room?

No. Indoor units at low fan speed are quieter than a room of children, and in a sleep room they are chosen for their quietest setting. The outdoor units are positioned away from windows and from the playground wherever the building allows.

There is more on noise, and what to ask for, on the noisy unit page.

Does air conditioning replace ventilation?

No. It cools and dehumidifies the air in the room but does not bring fresh air in. A classroom still needs its windows or its ventilation system for that.

If the problem is stuffiness rather than heat, we will say so.

Free survey and heat load calculation

Free on jobs over 5,000 pounds. You get a design drawing, a fixed price split into plant, installation, electrics and builders work, and a programme with the out-of-hours windows agreed before anyone starts.

Monday to Friday 9am to 7pm, Saturday 10am to 3pm, Sunday closed

Roughly how big is the space?

Page updated