The Samsung unit on its feet, with the isolator on the wall above it.

A 5kW heat pump
and seven column radiators in Richmond

A Samsung Gen 7 5kW high temperature unit, a cylinder with its buffer built in, and seven new column radiators.

  • Our own job, photographed on the day
  • Free survey and a fixed written price
  • MCS certified, NICEIC approved electrics

Accredited, and fitting the brands you know

NICEIC approved contractorGas Safe RegisterMCS certifiedRECC, Renewable Energy Consumer CodeTrustMark, Government Endorsed QualityVaillantClivetSamsungDaikinMitsubishi ElectricBosch

We installed a Samsung Gen 7 5kW high temperature heat pump in Richmond TW9 with a UK Cylinders Elite cylinder that has its buffer built in, and seven new column radiators. The combined cylinder saved finding space for a separate buffer tank.

The size came from a room-by-room heat loss survey, and the system is MCS certified with a 7-year Samsung warranty.

How the job was done

Step by step, in the photographs taken on site.

  1. 1

    Cylinder and buffer in one

    The UK Cylinders Elite 200/50 combines a 189-litre hot water cylinder with a 50-litre buffer in one unit, so the plant space holds one tank instead of two.

  2. The Samsung unit on its feet, with the isolator on the wall above it.
    2

    One clean pipe run

    The flow and return come up the wall as one insulated pair in a single clipped run, which is the difference between pipework that looks designed and pipework that looks added.

Richmond TW9: questions about this job

Is 5kW enough to heat a house?

For a smaller or well-insulated home, often yes. The room-by-room heat loss calculation decides, and a correctly sized small unit is more efficient than an oversized one.

Do column radiators work with a heat pump?

Yes. They have a large surface for their size, which suits a heat pump's lower water temperatures.

More of our finished work

Other jobs we have photographed. Tap one for the project.

All 34 projects
Daikin multi-split condenser in New Southgate N11 Air conditioning N11 New Southgate Daikin multi-split condenser Wall-mounted on brackets rather than stood on the ground, which is usually what a narrow side return leaves you, and the refrigerant lines dropped in a single trunked run. Read the case study Air source heat pump with roof-mounted solar in Winchmore Hill N21 Heat pump and solar N21 Winchmore Hill Air source heat pump with roof-mounted solar The panels sit across the rear pitch and the heat pump at the side of the house, which is the pairing that lets the pump run on its own generation through the middle of the day. Read the case study Samsung monobloc air source heat pump in Wood Green N22 Heat pump N22 Wood Green Samsung monobloc air source heat pump Stood on a levelled base built up out of the border rather than on soil, so the feet stay out of standing water and the unit does not settle out of level over a winter. Read the case study Samsung monobloc air source heat pump in Enfield EN3 Heat pump EN3 Enfield Samsung monobloc air source heat pump Set tight against the flank wall on anti-vibration feet, where it takes up none of the usable garden and the pipe run to the cylinder stays short. Read the case study Vaillant aroTHERM plus 7 kW air source heat pump in Enfield EN3 Heat pump EN3 Enfield Vaillant aroTHERM plus 7 kW air source heat pump Stood on rubber anti-vibration blocks on the existing patio slabs rather than on a new base, against the rear fence and beside the drainage the house already had. Read the case study Air source heat pump with solar and battery storage in Tottenham N15 Heat pump, solar and battery N15 Tottenham Air source heat pump with solar and battery storage The whole electrical side on one wall: inverter, battery modules and every isolator in reach, with the conduit dressed in straight runs so a fault years from now can be traced without stripping the wall. Read the case study Solar panels on ballasted frames, flat roof in Cricklewood NW2 Solar and battery NW2 Cricklewood Solar panels on ballasted frames, flat roof Low-tilt frames standing on the pebble finish of a new-build flat roof and held down by weight, so nothing is fixed through the waterproofing, with a clear strip left along the parapet to walk and work from. Read the case study Samsung monobloc air source heat pump in Camden NW1 Heat pump NW1 Camden Samsung monobloc air source heat pump Levelled on packers on an existing tiled patio rather than bolted through it, so the tiling stays intact and the unit still sits dead flat. Read the case study Samsung Gen 7 12kW high temperature heat pump in North Finchley N12 Heat pump N12 North Finchley Samsung Gen 7 12kW high temperature heat pump On wall brackets on the side of the house, clear of the ground, which keeps the side passage usable and the coil away from leaves and splashback. Read the case study Cascade pair of air source heat pumps in Barnet EN4 Heat pump EN4 Barnet Cascade pair of air source heat pumps Two machines in cascade on a flat roof, flow and return in insulated copper with isolating valves on each leg, so one can be shut down and worked on while the other keeps the building warm. Read the case study

Book a free heat pump survey

We measure every room, calculate the heat loss, check the radiators and the space for a cylinder, and send a written price with the grant already taken off. No cost and no obligation.

Monday to Friday 9am to 7pm, Saturday 10am to 3pm, Sunday closed

Which best describes the property?

Page updated