A Mitsubishi Ecodan, solar and a battery
in Winchmore Hill
An 11.2kW Mitsubishi Ecodan designed room by room to run at 55°C, with ten solar panels on the rear pitch and a 9.5kWh battery.
- Our own job, photographed on the day
- Free survey and a fixed written price
- MCS certified, NICEIC approved electrics
Accredited, and fitting the brands you know











We installed a Mitsubishi Ecodan 11.2kW heat pump with a 250-litre cylinder, a 4.45kW solar system of ten panels and a 9.5kWh battery in Winchmore Hill N21. Every room was checked against its existing radiators so the system could run at 55°C, which gives it a designed seasonal efficiency (SCOP) of 3.99.
A SCOP of 3.99 means almost 4 units of heat for every unit of electricity over a year. The £7,500 grant was applied, and at 32dB the unit sat within permitted development, so no planning application was needed.
How the job was done
Step by step, in the photographs taken on site.
-
1
Every room checked
The heat loss survey went room by room, comparing what each room loses on a cold day with what its existing radiator can give at 55°C. The design confirmed the radiators could stay, which kept the job simpler and the house familiar.
-
2Solar on the rear pitch
Ten panels across the rear roof slope give 4.45kW of generation. Through the middle of the day the heat pump can run on the house's own electricity, and the battery keeps the surplus for the evening.
-
3Sited off the fence
The Ecodan stands far enough off the boundary fence that the fan does not blow straight back off it, which is what makes a badly sited unit sound louder than it is.
Every photograph from the job
4 photographs, no faces, nothing staged.




Thinking about a heat pump?
What this job involved, applied to your own house.
Air source heat pumps
Whole-house heating with the £7,500 grant
Air source heat pumpsWhat a heat pump costs
Ten real quotations, before and after the grant
What a heat pump costsHeat pump or air conditioning?
Which one a house actually needs
Heat pump or air conditioning?Air-to-air heat pumps
Heats and cools, room by room
Air-to-air heat pumpsWinchmore Hill N21: questions about this job
What is SCOP?
The seasonal coefficient of performance: how many units of heat a heat pump delivers for each unit of electricity, averaged over a year. 3.99 means almost four. It depends on the design flow temperature, which is why the room-by-room survey matters.
Do I need planning permission for a heat pump?
Usually not, if the unit meets the permitted development conditions, including the noise limit. This one measured 32dB, well within them.
More of our finished work
Other jobs we have photographed. Tap one for the project.
Air conditioning
N11
New Southgate
Daikin multi-split condenser
Wall-mounted on brackets rather than stood on the ground, which is usually what a narrow side return leaves you, and the refrigerant lines dropped in a single trunked run.
Read the case study
Heat pump
N22
Wood Green
Samsung monobloc air source heat pump
Stood on a levelled base built up out of the border rather than on soil, so the feet stay out of standing water and the unit does not settle out of level over a winter.
Read the case study
Heat pump
EN3
Enfield
Samsung monobloc air source heat pump
Set tight against the flank wall on anti-vibration feet, where it takes up none of the usable garden and the pipe run to the cylinder stays short.
Read the case study
Heat pump
EN3
Enfield
Vaillant aroTHERM plus 7 kW air source heat pump
Stood on rubber anti-vibration blocks on the existing patio slabs rather than on a new base, against the rear fence and beside the drainage the house already had.
Read the case study
Heat pump, solar and battery
N15
Tottenham
Air source heat pump with solar and battery storage
The whole electrical side on one wall: inverter, battery modules and every isolator in reach, with the conduit dressed in straight runs so a fault years from now can be traced without stripping the wall.
Read the case study
Solar and battery
NW2
Cricklewood
Solar panels on ballasted frames, flat roof
Low-tilt frames standing on the pebble finish of a new-build flat roof and held down by weight, so nothing is fixed through the waterproofing, with a clear strip left along the parapet to walk and work from.
Read the case study
Heat pump
NW1
Camden
Samsung monobloc air source heat pump
Levelled on packers on an existing tiled patio rather than bolted through it, so the tiling stays intact and the unit still sits dead flat.
Read the case study
Heat pump
N12
North Finchley
Samsung Gen 7 12kW high temperature heat pump
On wall brackets on the side of the house, clear of the ground, which keeps the side passage usable and the coil away from leaves and splashback.
Read the case study
Heat pump
EN4
Barnet
Cascade pair of air source heat pumps
Two machines in cascade on a flat roof, flow and return in insulated copper with isolating valves on each leg, so one can be shut down and worked on while the other keeps the building warm.
Read the case study
Heat pump
E11
Leytonstone
Samsung monobloc air source heat pump
On its own slab set clear of the fence line, with the condensate taken away below ground level instead of being left to run across the paving and freeze.
Read the case study
Book a free heat pump survey
We measure every room, calculate the heat loss, check the radiators and the space for a cylinder, and send a written price with the grant already taken off. No cost and no obligation.